DOCUMENTATION HUB·LEVEL_2

Error Messages & Solutions — Ironframe GRC

REF_PATH: support/error-messagesSOURCE: APP_DOCUMENTS_DB

Error Messages & Solutions — Ironframe GRC

Common errors, log signatures, and remediation. Severity: Critical | High | Medium | Info.


Client / UI

Blank center dashboard after tenant switch

Severity: High
Cause: Cache invalidation during switch; or tenant UUID mismatch during load.
Fix: Refresh page; confirm tenant selected; upgrade to 42b9b56b+. Panels should show loading then data—not permanent blank.

Tenant isolation violation: attempted cross-tenant data access

Severity: Critical (client throw)
Cause: tenantFetch target UUID does not match active tenant.
Fix: Reselect tenant; clear cookies; re-login. Escalate if reproducible after single-tenant selection.

Pulse unavailable / Live feed unavailable

Severity: Medium
Cause: Sustainability stats endpoint failed and LKG not yet loaded.
Fix: Wait 60s; confirm tenant cookie; check stats route returns 200 with ok: true.


API responses

{ "ok": false, "error": "No active tenant." } (400)

Severity: Medium
Routes: Sustainability stats, carbon-pulse, exports handlers
Fix: Set ironframe-tenant cookie via switcher; pass x-tenant-id on server actions.

Dashboard fetch failed: 401

Severity: High
Fix: Re-authenticate Supabase session; verify middleware not blocking server actions.

TAS integrity probe → 503

Severity: Critical
Cause: Constitutional emergency (TAS gold mismatch or integrity failure).
Fix: Ops runbook — DOCS_OPERATIONS.md; do not mutate production data until cleared.

Sustainability stats → 503 (no LKG)

Severity: Medium
Cause: Bundle build threw and no SustainabilityMetric row for tenant LKG.
Fix: Seed tenant metrics; enable fallback env; check server logs [api/sustainability/stats].


Server logs

[ironbloom-carbon-ingress] {"reason":"missing_api_key",...}

Severity: Info (when fallback on) / Medium (when fallback off)
Fix: Set ELECTRICITY_MAPS_API_KEY or IRONWATCH_SUSTAINABILITY_FALLBACK_ENABLED=true. Restart dev server after env change.

[ironbloom-carbon-ingress] {"zone":"US-GD",...}

Severity: Info
Fix: Zone alias normalization maps US-GD → US-CO in 42b9b56b+; upgrade if zone still rogue.

[Ironwatch] stale mode audit failed

Severity: Medium
Fix: DB connectivity for audit log; non-fatal to heartbeat.

IRONWATCH_SUSTAINABILITY_FALLBACK (...) in SystemHealthLog

Severity: Info
Meaning: Heartbeat synthetic OK under fallback—expected on staging without live key.

IRONBLOOM_LIVE_SOURCE_REQUIRED

Severity: High
Cause: Utility rate poll without OpenEI/NREL credentials.
Fix: Configure OPEN_ENERGY_API_KEY or run utility poll in staging fallback mode.


Cron / integration

Cron 401 Unauthorized

Fix: Align IRONFRAME_CRON_SECRET in deployment with cron authorization header.

Cron 405 Method Not Allowed

Fix: Ensure GET handler exists on cron route (Epic 13 fix).

test:vercel-integration failure

Fix: Run locally with deploy URL; check scripts/vercel-integration-suite.mjs output for failing probe name.


Middleware

Redirect loop on sustainability URL with _api_key=

Fix: Middleware strips empty _api_key and injects bypass token when fallback enabled.